Marine Main Central Panel
FS12

(P/N: 80909)

Marine Main Central Panel FS12
Dimensions (L x W x H) max.179.2 mm x 199 mm x 109.5 mm
Weight1.3 Kg
Protection typeIP 44
Operating voltage2x 24 V DC (incl. broken wire monitoring)
Release circuitTwo as double-loop (incl. broken wire monitoring)
Detection lineOne with up to eight detectors in a row (incl. broken wire monitoring)

Approvals and Certificates

DNV  

Description

GL certified marine panel for fire detection and extinguishing with aerosol extinguishing generators. Flexibly adaptable for each application from 1 to 50 extinguishing generators via separate substations. These are connected via a double-loop release circuit. Up to eight detectors (smoke or thermal detectors) can be connected in series on the detection line. Detectors, substations, and extinguishing generators are permanently broken wire monitored and immediately report a fault message to the main panel.

Matching it :

MarineMarine
BuildingIndustrie

+49 40 713 752 - 0

egonharig@egonharig.de